Introduction: UV-Visible spectroscopy is a mature and well-established analytical technique used extensively in many industry sectors including Environmental Analysis, Pharmaceutical Testing, Food and Beverage Production etc. Spectroscopy is the measurement and interpretation of electromagnetic radiation absorbed or emitted when the molecules or atoms or ions of a sample moves from one energy state to another … Continue reading Ultra Violet Visible spectroscopy Principles
System suitability in HPLC Analysis
System suitability is to prove that system is working perfectly before the analysis on HPLC, GC, TOC analyser or any other system. It is required to done before every sample analysis. HPLC, short for High-performance liquid chromatography is a technique used for separating the components in a mixture. HPLC chromatographic technique is used in pharmaceutical industries for analysis. System suitability testing limits are … Continue reading System suitability in HPLC Analysis
Analyst Qualification Flowchart
PIC/S Guidelines for GMP in Pharmaceuticals
What is PIC/S: The Pharmaceutical Inspection Co-operation Scheme (PIC/S) is a non-binding, informal co-operative arrangement between Regulatory Authorities in the field of Good Manufacturing Practice (GMP) of medicinal products for human or veterinary use. It is open to any Authority having a comparable GMP inspection system. PIC/S presently comprises 54 Participating Authorities coming from all over the … Continue reading PIC/S Guidelines for GMP in Pharmaceuticals
SOP for Operation of Air Sampler
Air Sampler 1. OBJECTIVE 1.1 To lay down a procedure for operation of air sampler. 2. RESPONSIBILITY 2.1 Microbiologist – Quality Control – To follow the SOP. 2.2 Manager – Quality Control – To ensure the compliance of SOP. 3. PROCEDURE 3.1 Take the material required for sampling to the area for air sampling. 3.2 … Continue reading SOP for Operation of Air Sampler
Operation of Fume Hood in Quality Control Laboratory
1.0 OBJECTIVE To lay down a procedure for operation of fume hood. 2.0 RESPONSIBILITY 2.1 Chemist / Executive - Quality Control - to follow the procedure. 2.2 Supervisor / Manager – Quality Control to ensure adherence to the procedure. 2.3 Head - Quality Control for implementation and compliance. 3.0 PROCEDURE 3.1 OPERATION Ensure that the equipment … Continue reading Operation of Fume Hood in Quality Control Laboratory
Operation and Calibration of HPLC Pump for column washing
1.0 OBJECTIVE To lay down a procedure for the operation and calibration of High Pump for column washing Make: Shimadzu. 2.0 RESPONSIBILITY 2.1 Chemist / Executive - Quality Control - to follow the procedure. 2.2 Head - Quality Control for implementation and compliance. 3.0 PROCEDURE 3.1 OPERATION Ensure that the working area is clean and … Continue reading Operation and Calibration of HPLC Pump for column washing
What is Nitrosamine Impurities
What are nitrosamines? Nitrosamines, or more correctly N-nitrosoamines, refer to any molecule containing the nitroso functional group. These molecules are of concern because nitrosamine impurities are probable human carcinogens (a substance capable of causing cancer in living tissue). Although they are also present in some foods and drinking water supplies, their presence in medicines is … Continue reading What is Nitrosamine Impurities
Procedure for handling of Expired Raw Materials
1. OBJECTIVE 1.1 To lay down a procedure for handling of Expired Raw materials 2. RESPONSIBILITY Technical Assistant / Executive – Stores responsible to identify and segregate the expired material QA - Executive shall be responsible to verify and labeling of the on-line rejected/expired material, to verify the non-conformance(s) if any and communicate to … Continue reading Procedure for handling of Expired Raw Materials
Operation Procedure of Steam Boiler 6-Ton
1. OBJECTIVE 1.1 To lay down a procedure for Operation of steam Boiler 6--Ton. 2. RESPONSIBILITY Assistant Engineering - To Follow the SOP Executive Engineering - To comply the SOP 3. PROCEDURE 3.1 PRECAUTIONS 3.1.1 Do not by pass any safety interlock. 3.1.2 Check the mobrey air break switch for low-level indication giving blow down … Continue reading Operation Procedure of Steam Boiler 6-Ton